Loading...
By Amy Orciari Herman
Edited by David G. Fairchild, MD, MPH
Use of a single high-sensitivity cardiac troponin T (hs-cTnT) measurement plus electrocardiogram can rule out acute myocardial infarction in patients who present to the emergency department with chest pain, according to an Annals of Internal Medicine meta-analysis.
Researchers examined data from 11 prospective studies comprising over 9200 adults who presented with possible acute coronary syndrome and underwent both hs-cTnT measurement and ECG.
Roughly 31% of patients had negative test results — i.e., troponin below 0.005 µg/L plus no new ischemia on ECG — and were considered low risk for MI. Of these, 0.5% had an MI during the index admission. The overall sensitivity of the testing strategy was 98.7%; the negative predictive value was 99.3%.
Dr. Harlan Krumholz, editor-in-chief of NEJM Journal Watch Cardiology, comments: "This analysis indicates that a nonischemic ECG and a single negative hs-cTnT only misses about 1 in 100 MIs — and can provide rapid, useful information in an assessment." However, he stresses the importance of the authors' recommendation against using this strategy for people presenting within 3 hours of symptom onset, given that half of low-risk patients who had an MI had blood draws in that time frame.
Comment
LINK(S):
Annals of Internal Medicine meta-analysis (Free abstract)
Background: NEJM Journal Watch Emergency Medicine coverage of two decision rules for predicting acute MI (Your NEJM Journal Watch subscription required)