In both the MADIT-RIT trial (NEJM JW Cardiol Nov 6 2012) and the ADVANCE III trial (NEJM JW Cardiol May 15 2013), increasing implantable cardioverter-defibrillator (ICD) detection time for ventricular arrhythmias reduced activation of ICD therapy and even reduced mortality. Now, researchers have analyzed the ADVANCE III population for potential differences in hospitalization, length of stay, and costs. The analysis was confined to the first year of follow-up.
In this exploratory study of 1902 patients, there were significantly fewer hospitalizations in the patient programmed to a longer detection time (392 vs. 473). The longer-detection group also had significantly longer times to first overall hospitalization and to cardiovascular hospitali…